From the Journals

Fecal Immunochemical Test Performance for CRC Screening Varies Widely


 

Although considered a single class, fecal immunochemical tests (FITs) vary in their ability to detect advanced colorectal neoplasia (ACN) and should not be considered interchangeable, new research suggests.

In a comparative performance analysis of five commonly used FITs for colorectal cancer (CRC) screening, researchers found statistically significant differences in positivity rates, sensitivity, and specificity, as well as important differences in rates of unusable tests.

“Our findings have practical importance for FIT-based screening programs as these differences affect the need for repeated FIT, the yield of ACN detection, and the number of diagnostic colonoscopies that would be required to follow-up on abnormal findings,” wrote the researchers, led by Barcey T. Levy, MD, PhD, with University of Iowa, Iowa City.

The study was published online in Annals of Internal Medicine.

Wide Variation Found

Despite widespread use of FITs for CRC screening, there is limited data to help guide test selection. Understanding the comparative performance of different FITs is “crucial” for a successful FIT-based screening program, the researchers wrote.

Dr. Levy and colleagues directly compared the performance of five commercially available FITs — including four qualitative tests (Hemoccult ICT, Hemosure iFOB, OC-Light S FIT, and QuickVue iFOB) and one quantitative test (OC-Auto FIT) — using colonoscopy as the reference standard.

Participants included a diverse group of 3761 adults (mean age, 62 years; 63% women). Each participant was given all five tests and completed them using the same stool sample. They sent the tests by first class mail to a central location, where FITs were analyzed by a trained professional on the day of receipt.

The primary outcome was test performance (sensitivity and specificity) for ACN, defined as advanced polyps or CRC.

A total of 320 participants (8.5%) were found to have ACN based on colonoscopy results, including nine with CRC (0.2%) — rates that are similar to those found in other studies.

The sensitivity for detecting ACN ranged from 10.1% (Hemoccult ICT) to 36.7% (OC-Light S FIT), and specificity varied from 85.5% (OC-Light S FIT) to 96.6% (Hemoccult ICT).

“Given the variation in FIT cutoffs reported by manufacturers, it is not surprising that tests with lower cutoffs (such as OC-Light S FIT) had higher sensitivity than tests with higher cutoffs (such as Hemoccult ICT),” Dr. Levy and colleagues wrote.

Test positivity rates varied fourfold across FITs, from 3.9% for Hemoccult ICT to 16.4% for OC-Light S FIT.

The rates of tests deemed unevaluable (due to factors such as indeterminant results or user mistakes) ranged from 0.2% for OC-Auto FIT to 2.5% for QuickVue iFOB.

The highest positive predictive value (PPV) was observed with OC-Auto FIT (28.9%) and the lowest with Hemosure iFOB (18.2%). The negative predictive value was similar across tests, ranging from 92.2% to 93.3%, indicating consistent performance in ruling out disease.

The study also identified significant differences in test sensitivity based on factors such as the location of neoplasia (higher sensitivity for distal lesions) and patient characteristics (higher sensitivity in people with higher body mass index and lower income).

Dr. Levy and colleagues said their findings have implications both in terms of clinical benefits and cost-effectiveness of CRC screening using FITs.

“Tests with lower sensitivity will miss more patients with CRC and advanced polyps, and tests with higher sensitivity and lower PPV will require more colonoscopies to detect patients with actionable findings,” they wrote.

Pages

Recommended Reading

Liver Transplant Delays Progression in Colorectal Metastasis
Federal Practitioner
Cold Snare Resection Safe for Large Nonpedunculated Colorectal Polyps
Federal Practitioner
Is Your Patient Too Old for a Colonoscopy?
Federal Practitioner
Closing the Gap: Priority Zones Identified for CRC Screening in Hispanic/Latino Populations
Federal Practitioner
Aspirin for CRC Prevention May Work Best in Adults With Unhealthy Lifestyles
Federal Practitioner
SBRT vs Surgery in CRC Lung Metastases: Which Is Better?
Federal Practitioner
Diet Rich in Processed Foods Linked to Elevated Risk for Colorectal Cancer
Federal Practitioner
In Colorectal Cancer, Donating Half a Liver Could Save Lives
Federal Practitioner
Five Key Measures to Ensure a Quality Colonoscopy
Federal Practitioner
Mortality Risk From Early-Onset CRC Higher in Rural, Poor Areas
Federal Practitioner