SAN FRANCISCO — Primary care providers placed contraceptive intrauterine devices (IUDs) incorrectly nearly twice as often as ob.gyn. providers at a single institution, according to data presented at the annual meeting of the American College of Obstetricians and Gynecologists.
“Adequate training for providers regarding proper techniques for IUD insertion is imperative for good clinical practice, patient satisfaction, and effectiveness of the LARC [long-acting reversible contraceptive],” Kerrilyn Hewell, MD, a fourth-year resident ob.gyn. at Southern Illinois University in Springfield, reported. “Primary care providers are often seen for contraception management. Therefore, the significantly higher malpositioned rate indicates the need to implement an enhanced simulation/education curriculum for IUD insertion.”
Kevin Ault, MD, a professor and chair of the Department of Obstetrics and Gynecology at Western Michigan University Homer Stryker M.D. School of Medicine, was not involved in the study but said it was not surprising.
“The reasons for obtaining an ultrasound are not discussed in the abstract, so the primary care physicians may have found more problems by ordering more ultrasounds,” Dr. Ault told this news organization. “The takeaway would be to order an ultrasound if you are unsure of placement of the IUD. Malpositioned IUDs may be at risk for expulsion and women may be at risk for unplanned pregnancy.”
The researchers conducted a retrospective review of all adult women’s ultrasounds from the ob.gyn. department of the Southern Illinois University School of Medicine between 2017 and 2020 in which an IUD was documented. Two physicians certified by the American Institute of Ultrasound in Medicine interpreted the images to determine whether the IUD was positioned correctly.
Among 602 ultrasounds included, 562 of the IUDs were placed by an ob.gyn., and 40 were placed by a primary care provider. Most of the IUDs were properly positioned (82%) while 18% were malpositioned. When the researchers compared positioning by specialty, they found that 30% of the malpositioned IUDs had been placed by primary care providers, compared to 17% of malpositioned IUDs placed by an ob.gyn. (P = .043).
The most common type of malpositioning was placement low in the cervix (40.4%) or low but not in the cervix (25.7%). Other types of malpositioning included a deviated axis, the device being inverted or transverse, the IUD arms being folded, the device being embedded, or the device placed outside the uterus.
Of the 136 IUDs placed by an ob.gyn. resident, 17% were malpositioned. Only 6 IUDs had been placed by a primary care resident, and one was malpositioned. Among midlevel providers, 17% of 78 IUDs placed by an ob.gyn. and 33% (5) of 15 IUDs placed by a primary care provider were malpositioned. Among attending physicians, 18% of the 348 IUDs placed by an ob.gyn. and 30% of the 40 IUDs placed by a primary care provider were malpositioned.
No external funding was noted, and the authors and Dr. Ault had no disclosures.