En Bloc Joystick Reduction of a Comminuted Intra-articular Distal Radius Fracture: A Technical Trick
Evan Siegall, MD, and Bruce Ziran, MD
A patient with a 1-month-old intra-articular distal radius fracture (treated closed in a splint) presented with an unacceptable degree of pain and stiffness caused by shortening and dorsal angulation of the distal radius. The fracture was comminuted with 4 or 5 distinct fragments, several involving the articular surface. Surgical correction was attempted. During the procedure, it was noted that, though the distal radius was shortened and angulated, there was actually acceptable congruity of the articular surface itself, despite the intra-articular nature of the fracture. Bone quality was poor and healing incomplete. Thus, we were concerned the currently congruous articular surface would fall apart with manipulation. Given this situation, we used a unique scaffolding technique with Kirschner wires placed in perpendicular fashion to both hold the articular surface intact and manipulate it en bloc. This technique is a simple way to turn a complex fracture into an easily reduced 2-part fracture.