Latest News

False-positive breast cancer screening likely over 10-year period


 

JAMA NETWORK OPEN

Breast cancer screening modality has less effect on the probability of false-positive results than screening interval, patient age, and breast density according to a new study comparing digital breast tomosynthesis (DBT) with digital mammography.

Although DBT was associated with a modest improvement in recalls for false-positive results compared with mammography, about half of women in both groups received at least one false-positive result over a 10-year period of annual screening, reported senior author Diana L. Miglioretti, PhD, from the University of California, Davis, and colleagues.

By contrast, the authors reported “substantial reductions” in false-positive recalls with biennial screening. Specifically, while annual mammography and DBT resulted in cumulative 10-year false-positive recall rates of 56.3% and 49.6% respectively, biennial rates were 38.1% and 35.7%.

The comparative effectiveness study, published in JAMA Network Open, included 903,495 women who underwent 10 years of breast cancer screening at 126 radiology facilities in the Breast Cancer Surveillance Consortium. The mean age of participants was 57.6 years, and 46% of them had dense breasts. A total of 2,969,055 screening exams were performed (15% DBT), with each woman receiving a mean of 3.3 exams over 10 years. Most participants (71.8%) had annual exams, while 16.8% had biennial, with the remainder being performed at intervals of 3 years or more.

Investigators looked at the cumulative rate of three kinds of false-positive results over 10 years: false-positive recalls for further imaging, false-positive short-interval follow-up recommendations, and false-positive biopsy recommendations. A result was considered false positive if there was no diagnosis of invasive carcinoma or ductal carcinoma in situ within 1 year of the screening examination and before the next screening examination.

Overall, across all screening intervals, and after adjusting for age and breast density, the percentage of false-positive results was slightly lower for DBT vs. mammography: 7.6% vs. 9.0%, respectively, for false-positive recalls; 1.8% vs. 2.1%, respectively, for false-positive short-interval follow-up recommendations; and 1.1% vs. 1.2% for false-positive biopsy recommendations. “We did not observe consistent clinically meaningful differences in the cumulative probabilities of false-positive short-interval follow-up or biopsy recommendation by screening modality,” they noted, adding that, although DBT provided “modest” reductions in false-positive recalls, compared with mammography (2.4% less for biennial screening and 6.7% less for annual screening), “nonetheless, this percentage equates to many thousands of individuals in absolute numbers, especially for annual screening, which is the dominant practice in the U.S.”

The authors also noted that, regardless of screening modality, all three types of false-positive results were substantially lower for biennial versus annual mammograph, and depended on age and breast density. The highest cumulative rates of false-positive results occurred in women aged 40-49 years (68.0% with annual digital mammography and 60.8% with annual DBT). Women with extremely dense breasts had the highest probability of all three types of false positive, which “may be due to the lack of interspersed fat within dense fibroglandular tissue, with the contrast between the fat and tissue being a requirement for more accurate detection of suspicious features by interpreting radiologists.”

The study findings “offer new information about the potential harms of repeated screening, which may be used to inform screening guidelines and decision-making between individuals and their physicians. However, it is important to weigh these and other potential harms with potential benefits of earlier diagnosis. … Women at high risk of an advanced cancer under biennial screening, including some women with dense breasts, may reduce their risk with annual screening,” they suggested.

Although DBT is now widely used in the United States, amid growing optimism about its superiority over digital mammography, this study reminds clinicians to counsel patients appropriately, according to Lydia E. Pace, MD, from Brigham and Women’s Hospital in Boston. “Unfortunately, the growing availability of DBT does not substantially change the likelihood that women will experience a false-positive result over years of regular mammograms,” she wrote in an invited commentary published with the study. She noted that, although many women tolerate false-positive results, “they are associated with at least transient anxiety as well as time, inconvenience, and expense. More information is needed to understand the association of DBT with overdiagnosis, which is the more clinically important harm of screening.”

The study was funded by the National Cancer Institute. Dr. Miglioretti and Dr. Pace reported no conflicts of interest. One coauthor of the study is an unpaid consultant for Grail, for the STRIVE study, and another coauthor receives personal fees from Grail for work on a data safety monitoring board. No other disclosures were reported.

Recommended Reading

Poor trial representation tied to worse breast cancer survival
MDedge ObGyn
Variants of nine breast cancer genes associated with severe disease
MDedge ObGyn
Should all women be routinely screened for lung cancer?
MDedge ObGyn
Aspirin fails to inhibit breast cancer recurrence
MDedge ObGyn
MRI with mammogram reduces breast cancer mortality by more than 50% in high-risk women
MDedge ObGyn
Heavy drinking in your 20s has lasting impact on cancer risk
MDedge ObGyn
Appropriate cancer screening for women with dense breasts
MDedge ObGyn
FDA approves first PARP inhibitor for early BRCA+ breast cancer
MDedge ObGyn
Doctors treat osteoporosis with hormone therapy against guidelines
MDedge ObGyn
Breast density linked to familial breast cancer risk
MDedge ObGyn