Case Reports

Neonatal Physeal Separation of Distal Humerus During Cesarean Section

Author and Disclosure Information

 

References

As our patient’s instability was noted during surgery, we performed percutaneous pinning after arthrography-assisted closed reduction. We considered using 2 lateral pins for fixation, but, after the first pin was placed, fluoroscopic stress testing with the patient under anesthesia demonstrated adequate stability. A second, smaller pin could have been used to control rotation, if needed. Medial pin placement that avoids the ulnar nerve is difficult in the newborn elbow; medial pins should probably be avoided in the newborn, if possible.

Early diagnosis and treatment are essential. Late diagnosis was reported to lead to complications such as varus deformity and restriction of joint ROM.4

Our patient healed without any complications and achieved full ROM. Long-term follow-up is needed to diagnose any physeal bar that might lead to secondary deformities.

Conclusion

Cesarean section is reported to reduce birth complications, but it might cause fractures of the femur and humerus.1 Avoiding application of excessive traction to the forearm can prevent physeal separation of the distal humerus. This entity should be kept in mind as a potential complication of cesarean section. Arthrography is helpful in treatment and may help avoid unnecessary open reduction.

Pages

Recommended Reading

Applying Computer-Assisted Navigation Techniques to Total Hip and Knee Arthroplasty
MDedge Surgery
From Wall Graft to Roof Graft: Reassessment of Femoral Posterior Cruciate Ligament Positioning
MDedge Surgery
Surgeons' Perception of Fluoroscopic Radiation Hazards to Vision
MDedge Surgery
Navigation in Total Knee Arthroplasty: Truth, Myths, and Controversies
MDedge Surgery
Locked Knee Caused by Lateral Meniscal Capsular Disruption: Verification by Magnetic Resonance Imaging and Arthroscopy
MDedge Surgery
Computer Navigation Systems in Unicompartmental Knee Arthroplasty: A Systematic Review
MDedge Surgery
Perioperative Differences in Conventional and Computer-Assisted Surgery in Bilateral Total Knee Arthroplasty
MDedge Surgery
Spontaneous Septic Arthritis of the Lumbar Facet Caused by Methicillin-Resistant Staphylococcus aureus in an Otherwise Healthy Adolescent
MDedge Surgery
Multifocal Intraosseous Ganglioneuroma
MDedge Surgery
The Role of Computed Tomography for Postoperative Evaluation of Percutaneous Sacroiliac Screw Fixation and Description of a “Safe Zone”
MDedge Surgery